当前位置: 首页 >仪器仪表>压力仪表>压力表 >WIKA PGS43.100 PGS43.160 不锈钢耐震膜片式微压电接点压力表

WIKA PGS43.100 PGS43.160 不锈钢耐震膜片式微压电接点压力表

起批量
1台

产品属性

品牌
其他
型号
PGS43.100 PGS43.160
类型
其他
精度等级
其他
公称直径
其他
环境温度
-40-70
加工定制
其他

WIKA PGS43.100 PGS43.160
不锈钢耐震膜片式微压电接点压力表
Diaphragm pressure gauge with switch contacts
Models PGS43.1x0, stainless steel version


Diaphragm pressure gauge model PGS43.100 with
switch contact model 831.21


   Applications
     Control and regulation of industrial processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar
     Monitoring of plants and switching of electric circuits
     For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience
     Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction


   Special features
     High reliability and long service life
     Wide choice of special materials
     Up to 4 switch contacts per instrument
     Also available with liquid-filled case for high dynamic pressure loads or vibrations
     Gauges with inductive contacts for use in hazardous areas with ATEX approval
     Gauges with electronic contact for PLC applications

 

   Description
    Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the model PGS43.1x0 switchGAUGE can be used.


    Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are
mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
    The set pointer can be adjusted using a removable adjustment key in the window.

Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.


    The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.
    As switch contacts magnetic snap-action contacts, reed switches, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.
    For further information on the different switch contacts please see data sheet AC 08.01.

 

   Standard version


   Nominal size in mm
    100, 160


   Accuracy class
    1.6


   Scale ranges
    0 ... 25 mbar to 0 ... 250 mbar (flange Ø 160 mm)
    0 ... 400 mbar to 0 ... 25 bar (flange Ø 100 mm)
    or all other equivalent vacuum or combined pressure and vacuum ranges


   Pressure limitation
    Steady: Full scale value
    Fluctuating: 0.9 x full scale value


   Overpressure safety
    5 x full scale value, however max. 40 bar


   Permissible temperature
    Ambient: -20 … +60 °C
    Medium: +100 °C maximum


   Temperature effect
    When the temperature of the measuring system deviates
    from the reference temperature (+20 °C):
    max. ±0.8 %/10 K of full scale value


   Process connection with lower measuring flange
    Stainless steel 316L, G ½ B (male), 22 mm flats


   Pressure element
    ≤ 0.25 bar: Stainless steel 316L
    > 0.25 bar: NiCr-alloy (Inconel)


   Pressure chamber sealing
    FPM/FKM


   Movement
    Stainless steel


   Dial
    Aluminium, white, black lettering


   Pointer
    Instrument pointer: Aluminium, black
    Set pointer: red


   Case with upper measuring flange
    Stainless steel, with blow-out device in case back
    With safety version: With solid baffle wall (Solidfront) and
    blow-out back


    Window
    Laminated safety glass


   Bezel ring
    Cam ring (bayonet type), stainless steel

 

   Electrical connection
    Terminal box


   Ingress protection
    IP 54 per EN 60529 / IEC 529


   Switch contacts

   Magnetic snap-action contact model 821
     No control unit and no extra power supply required
     Direct switching up to 250 V, 1 A
     Up to 4 switch contacts per measuring instrument


   Inductive contact model 831
     Long service life due to non-contact sensor
     Additional control unit required (model 904.xx)
     With corresponding control unit suitable for use in zone 1 / 21 (2 GD) hazardous areas
     Low effect on the indication accuracy
     Fail-safe switching at high switching rates
     Insensitive to corrosion
     Up to 3 switch contacts per measuring instrument


   Electronic contact model 830 E
     For direct triggering of a programmable logic controller (PLC)
     2-wire system (option: 3-wire system)
     Long service life due to non-contact sensor
     Low effect on the indication accuracy
     Fail-safe switching at high switching rates
     Insensitive to corrosion
     Up to 3 switch contacts per measuring instrument


   Reed switch model 851
     No control unit and no extra power supply required
     Direct switching up to 250 V, 1 A
     Also suitable for direct triggering of a programmable logic controller (PLC)
     Free from wear as without contact
     Up to two change-over contacts per measuring instrument


   Switching function
    The switching function of the switch is indicated by function index 1, 2 or 3.
    Model 8xx.1: Contact makes (clockwise pointer motion)
    Model 8xx.2: Contact breaks (clockwise pointer motion)
    Models 821.3 and 851.3: Change over; one contact breaks
                             and one contact makes simultaneously
                             when pointer reaches set point
    For further information please see data sheet AC 08.01, electrical switch contacts

 

   Options
     Other process connection
     Sealings (model 910.17, see data sheet AC 09.08)
     Liquid filling (filling liquid silicone oil M50, ingress protection IP 65)
     Overpressure safety: 10 x full scale value, max. 40 bar
     Vacuum safe to -1 bar
     Max. medium temperature +200 °C
     Higher indication accuracy, class 1.0 and 0.6
     Open connecting flanges per DIN/ASME from DN 15 to DN 80 (preferred nominal widths DN 25 and 50 or DN 1" and 2"; see data sheet IN 00.10)
     Wetted parts lined/coated with special materials such as PTFE, Hastelloy, Monel, nickel, tantalum, titanium, silver (gauges with accuracy class 2.5)
     Inductive contacts also in safety version (SN, S1N)

 

   Instruments with special approvals 1)
     Pressure switch per VdTÜV code of practice 100
     SIL2 approval
     DVGW declaration for the use in gas supply systems
     DIN/DVGW registration: Pressure switch per EN 1854
     Gost standard approval (Russia)
     Design approval for connection to hazardous zone 0
   1) Specification on request

 

   Dimensions in mm
    switchGAUGE model PGS43.100 with switch contact model 821, 831 or 830 E

 

         

        switchGAUGE model PGS43.100 (safety version) with switch contact model 821, 831 or830 E
       

    switchGAUGE model PGS43.160 with switch contact model 821, 831 or 830 E

   

    switchGAUGE model PGS43.160 (safety version) with switch contact model 821, 831 or 830 E

   

    switchGAUGE model PGS43.063 with switch contact model 851.3 or 851.33

   

    switchGAUGE model PGS43.160 with switch contact model 851.3 or 851.33

   

    Ordering information
    Model / Nominal size / Type of contact and switching function / Scale range / Connection size / Options

 

   

欢迎致电咨询订购WIKA PGS43.100 PGS43.160 不锈钢耐震膜片式微压电接点压力表

电话: 56291930

传真:

QQ:823377546 36968574

邮箱:sales@zoriver.cn

公司官网:http://www.zoriver.cn              http://www.zoriver.com.cn

 


规格参数
型号 PGS43.100 PGS43.160   环境温度 -40-70  (℃)
品牌 WIKA/威卡   类型 隔膜压力表  
精度等级 1.0   公称直径 100 160  
加工定制 是   测量范围 0-250mbar  
联接型式 G1/2      
包装参数
体积(m²)
产品重量(kg)
代理商供货
退换货规则说明
申请方式

1,在线申请:您可以在"我的订单"中找到您需要退换修的订单,点击”申请退款/退货”即可。我们的工作人员会在2个工作日 内和您取得联系,你可以随时在线查看你的退换修状态。

注意事项

1,“7天无理由退换货”适用于买家在收到货品后因不满意货品希望退换货的情形。

2,因质量问题产生的退换货,邮费由平台供应商承担(此质量问题为货品破损或残缺)。非商品质量问题的退换货,应由买家承担往返运费。

3,退换货要求退换的商品在平台供应商收到时有完整的外包装、配件、标牌等;待退换的物品被用过、人为破坏或标牌拆卸的不予退换。

(1)符合退货政策的商品必须包装完整、数量准确且不影响再次销售,退货的同时必须退回相应的发票和相关文件。

(2)请对寄回的商品妥善包装,若是退换货过程中由于包装过于简单造成的物流损坏,平台供应商不承担商品完整责任。

(3)发票需单独寄送。退换货时,如涉及发票退回,请您不要将发票放在货物中一起寄送,平台供应商客服人员将和您确认发票寄送地址,避免丢失。

4,退货商品的价款到账时间因支付方式的不同而有所差异,具体应参照相关银行或支付工具的说明提示,平台供应商不对退换货费用的到账时间做任何形式的保证。

特别提醒:为避免由于商品滞留造成的经济损失,所有退换货商品,买家应在所规定之时间内发回(以物流签收时间次日起7天内为准),超过规定时间仍不能将退换商品发出的,平台供应商将不予接受该退换货商品。

联系方式
注意:1 . 使用电话联系可有效保证您的号码隐私不被泄露
          2 . 拨打后可在后台进行拨打记录查询
          3 . 成交后在会员中心确认可获得积分
联系人:仇立新 (市场部/市场经理)
电话:15910733293
给我留言
注意:1. 供应商将在24小时内给您回复,回复内容将以短信形式发送至您手机。
2. 对产品的尺寸,质量,规格,库存等方面技术问题进行咨询,我们有专人进行回复,因厂家随时会更改产品的相关信息,请以厂家实际产品为准。
咨询产品:
WIKA PGS43.100 PGS43.160 不锈钢耐震膜片式微压电接点压力表
联系电话:
联系人:
留言详情: